Outline of Functional Qualification Test

By evaluating the influence of environmental conditions and reflecting this in the design and manufacturing of the active valve, it performs safety-related functions without damaging the valve under any conditions during the installation life of the active valve, it is a series of actions to prove, document, and maintain operability in accordance with ASME QME-1(KEPIC MFC) to meet the performance requirements of the system, and the environmental conditions are as follows.

  • Temperature, pressure, humidity, radiation, electromagnetic waves, vibration, etc.
  • Earthquake, natural environment and design-based accidents
Items of Functional Qualification Test
성능검증 항목을 나타내는 표
Division Performance Verification Items APOV ASOCV APRV
1 Pre-exam inspection
2 Performance and Leakage - Baseline x x
3 Determination of the fundamental frequency when applicable
4 Environment and aging degradation simulation when applicable when applicable x
5 Interim inspection x
6 Cycle test (room temperature and high temperature) when applicable x
7 End load test x
8 Seismic test when applicable
9 Discharge pipe and reaction load verification test x x
10 Seismic resistance and discharge pipe load combination test x x
11 External environmental test x x
12 Heat effect test x x
13 Flow Interruption and Demonstration of Functional Capability x
14 Performance and Leakage - Final x x
15 Post-exam inspection
  • APOV : Active Power Operated Valve
  • ASOCV : Active Self Operated Check Valve
  • APRV : Active Pressure Relief Valve
Status of holding major facilities
성능검증 항목을 나타내는 표
Division Test Equipment Equipment Name Equipment Details Maximum Facility Capacity
(at the time of testing)
1 Performance Test Device Test Main Vessel Cycle and flow interruption test Fluid storage test Max. fluid storage : 20.1㎥
Max. test pressure : 220 kg/㎠ (21,574 kPa)
Max. test temperature : 400℃
2 Heat Exchanger Test fluid (Water) heating Max. heating pressure : 220 kg/㎠ (21,574 kPa)
Max. heating temperature : 400℃
3 Steam Boiler Steam production for test Adjustable pressure: 50∼3200 Psig (345~22,063 kPa)
Max. temperature : 375 ℃
Auxiliary equipment : Boiler Feed Pump