Diagnostic Test


Samshin Limited provides diagnostic test service for th power operated valves in nuclear power plants according to the regulations, and customer's purchaseorder. through diagnostic test, following critical parameters can be monitored and evaluated:


A. Valve stem torque and thrust
B. Actuator output torque
C. Spring pack movement
D. Motor power
E. Motor current
F. Control switch actuation time


POV valve diagnostic test

MOV ATV diagnostic test

MOV MCC diagnostic test